Avaliação do torque final e torque reverso de diferentes designs de implantes

Avaliação do torque final e torque reverso de diferentes designs de implantes

Vol. 8 – Número 30 – 2017   CADERNO DE IMPLANTODONTIA   Artigo original/Original article   Página 28-33 Avaliação do torque final e torque reverso de diferentes designs de implantes Evaluation of insertion and removal torque of different designs of dental implants    Vinicius Flores Cielo1 Fábio Shiniti Mizutani2 Guilherme Camponogara de Freitas3       Resumo O objetivo do estudo foi comparar o design de três tipos de implantes na obtenção da estabilidade primária, através da avaliação do torque final e contra-torque. Trinta implantes da marca Bionovattion® foram usados nesse estudo, sendo 10 cilíndricos (Biodirect® Cilíndrico),10 cônicos (Biodirect® Cônico) e 10 cônicos autoperfurantes (Biodirect® XP). Todos os implantes foram instalados por um único pesquisador, em um bloco de poliuretano rígido de 13 X 18 X 4 centímetros (Nacional Ossos®, Jaú, São Paulo, Brasil). Após a instalação dos implantes, o torque final de inserção e o contra-torque foram registados em Ncm com a utilização de um torquímetro digital portátil Lutron® TQ 8800 (Lutron, Taipei, Taiwan). Como resultado houve diferença significante (p< 0,05) entre os três grupos no torque e no contra-torque, sendo que o grupo cônico autoperfurante apresentou valores mais elevados, seguido pelo grupo de implantes cônicos e cilíndricos, respectivamente. Concluiu-se que os implantes cônicos auto-perfurantes apresentaram maior estabilidade primária, sendo indicados para ossos de baixa densidade, bem como os implantes cônicos convencionais, mesmo esses mostrando menores valores de torque e contra-torque. Já os implantes cilíndricos são indicados para situações em que a densidade óssea é maior, como nos casos de osso tipo I e II.    Descritores: Osseointegração, Torque, in vitro, implantes dentários.   Abstract The study aimed to compare the design of three types of implant to obtaining primary stability by evaluating the final torque and counter-torque. Thirty implants Bionovattion® brand were used in this study, 10 cylindrical (Biodirect® Cylindrical), 10 tapered (Biodirect® tapered), and 10 tapered self-drilling (Biodirect® XP). All implants were installed by a single researcher, in a rigid polyurethane block 13 X 18 X 4 cm (Nacional Ossos®, Jau, São Paulo, Brazil). After installing the implant, insertion torque and counter-torque were recorded in Ncm with the use of a torque wrench portable digital Lutron® TQ 8800 (Lutron, Taipei, Taiwan). There were significant difference (p <0.05) between the three groups in torque and counter-torque, and the tapered self-drilling group showed higher values, followed by tapered implant group and cylindrical, respectively. It was concluded that the tapered self-drilling implants showed greater primary stability, being indicated for low bone density, as well as conventional tapered implants, even those showing lower values of torque and counter-torque. Then, the cylindrical implants are indicated for situations which the bone density is higher, as in cases of bone type I and II.    Descriptors: Osseointegration, torque, in vitro, dental implants.   1 Prof. Universitário – Centro Universitário Franciscano. 2 Esp. em Implantodontia – UNICASTELO, Me. em Implantodontia – SLMandic, Prof. do curso de Pós-Graduação em Implantodontia – UNICSUL. 3 Me. em Periodontia – UFSM, Prof. Universitário – Centro Universitário Franciscano.

This content is restricted to site members. If you are an existing user, please log in. New users may register below.

Existing Users Log In
   
New User Registration
*Required field
Abrir conversa
Precisa de ajuda?