Estudo clínico e laboratorial do percentual de degradação das forças geradas por elastômeros em cadeia

Estudo clínico e laboratorial do percentual de degradação das forças geradas por elastômeros em cadeia

Vol. 9 – Número 34 – 2016 Artigo original/Original article Página 30-35 Estudo clínico e laboratorial do percentual de degradação das forças geradas por elastômeros em cadeia Clinical and laboratory study of the percentage force decay on elastomeric chains George Nunes Bueno1 Marcio Alexandre Cardoso2 Ione Helena Vieira Portella Brunharo3 Alvaro de Moraes Mendes4 Resumo São objetivos deste trabalho avaliar clínica e laboratorialmente a intensidade das forças liberadas por elastômeros em cadeia pré-estirados. A intensidade e o percentual de degradação das forças elásticas liberadas por duas marcas de elastômeros em cadeia (3M – 3MU e American Orthodontics – AO) foram avaliadas em solução de saliva artificial e no meio bucal. As forças liberadas durante a realização do experimento foram quantificadas através de uma máquina de ensaios de tração (EMIC). Todos os grupos apresentaram forças menores geradas pelos elastômeros em três semanas, quando comparadas com as respectivas forças iniciais. Houve uma grande variação das médias apresentadas em relação aos períodos de tempo intermediários avaliados para os dois meios e para as duas marcas testadas. No final de um período de 3 semanas, os valores médios das forças geradas pelos elastômeros da marca AO foram mais elevados do que os gerados por elastômeros da marca 3MU. Após o período de 3 semanas ambas as marcas de elastômeros geraram forças suficientes para produzir o movimento dentário.  Descritores: Ortodontia, elastômeros, resistência à tração. Abstract The objective of this study was to evaluate clinically and in the laboratory the intensity of forces delivered by prestretched elastomeric chains. The intensity and percentage of force decay of two commercial brands of elastomeric chains, 3M Unitek (3MU) and American Orthodontics (AO), were evaluated in artificial saliva and in the oral environment. The forces generated during the experiment were quantified by means of a tensile testing machine (EMIC). All groups showed a reduction in the forces generated by the elastomers within a 3-week period compared with their respective initial (baseline) forces. There was a wide variation in the means achieved in those time periods in which the two environments and the two brands were assessed. At the end of a 3-week period, the mean values of the forces generated by AO elastomers were higher than those generated by 3MU elastomers. After the 3-week period both brands of elastomers still generated enough force to produce dental movement. Descriptors: Orthodontics, elastomers, tensile strength. 1 Especialista e Mestre em Ortodontia – UERJ, Doutorando em Saúde Coletiva – UFES. 2 Especialista e Mestre em Ortodontia – UERJ. 3 Doutora em Ortodontia, Professora Visitante – UERJ. 4 Doutor e Mestre em Ortodontia, Professor Adjunto da Disciplina de Ortodontia – UERJ.

Este conteúdo é restrito a membros do site. Se você é um usuário registrado, por favor faça o login. Novos usuários podem registrar-se abaixo.

Login de Usuários
   
Registro de Novo Usuário
*Campo obrigatório
Abrir conversa
Precisa de ajuda?