Estudo in vitro da resistência ao cisalhamento dos compósitos Concise Ortodôntico e Ortho-One.

Estudo in vitro da resistência ao cisalhamento dos compósitos Concise Ortodôntico e Ortho-One.

Orthodontic Science and Practice Volume 5 – Número 20 – Ano 2012 Artigo Original/Original Article Página 499-504 Estudo in vitro da resistência ao cisalhamento dos compósitos Concise Ortodôntico e Ortho-One. “In vitro” study of shear bond strength of the composite concise orthodontic and Ortho-One. Ulisses Coelho1 Edson do Rocio Meister2 Sérgio Paulo Hilgenberg3 Wagner Izumi Sawada Germiniani4 Resumo Este estudo avaliou a resistência adesiva ao cisalhamento (RAC) e o índice de adesivo remanescente (IAR) na colagem de bráquetes metálicos com as resinas Concise Ortodôntico / 3M e Ortho-One / Bisco. Foram construídos corpos de prova com 60 pré-molares humanos superiores divididos aleatoriamente (n=30) para cada um dos grupos. O procedimento de colagem foi realizado conforme as instruções de cada fabricante. O ensaio de cisalhamento foi realizado com uma máquina MTS 810. Os resultados mostraram uma média de RAC para as resinas Concise e Ortho-One de 29,99±15,89 MPa e de 22,52±12,2 MPa, respectivamente. A análise estatística pelo teste t de Student não mostrou diferença estatística significante quanto à RAC (p>0,05). Para avaliação do IAR, foi utilizado o teste não paramétrico de Kruskal-Wallis, o qual não mostrou diferença estatística significativa quanto ao padrão de descolagem (p=0,361). Conclui-se que não há diferença significativa entre as resinas testadas e ambos os materiais apresentaram padrões aceitáveis para um bom desempenho clínico. Descritores: Colagem, bráquetes, resistência ao cisalhamento. Abstract This study assessed the shear bond strength and adhesive remanescent index (ARI) when bonding metallic brackets using the composites Concise Orthodontic Bonding System/3M and Ortho One/Bisco. Sixty human upper premolars were used divided randomly in two groups. Bonding procedure was conducted following each manufacturer’s instructions. The results showed that the mean shear bond strength with Concise and Ortho One ranged between 29,99 ± 15,89 MPa and 22,52 ± 12,2 MPa, respectively. Data were submitted to statistical analysis by the t test of Student (showed no significant statistical differences between the composites) (p>0,05). In evaluation of ARI was utilized Kruskal-Wallis test without difference statistical significance. Both the materials showed acceptable patterns for a good clinical performance. Descriptors: Bonding, brackets, shear bond strength. 1 Prof. Dr. Ass. da disciplina de Ortodontia do curso de Odontologia da UEPG, Coord. do curso de especialização em Ortodontia na UEPG. 2 Prof. Ms. Ass. da disciplina de Materiais Dentários do curso de Odontologia da UEPG. 3 Esp. em Ortodontia pela UEPG e Ms. em Clínica Integrada no Programa de Pós-Graduação em Odontologia da UEPG. 4 Esp. em Ortodontia pela UEM-PR e Mestrando em Clínica Integrada no Programa de Pós-Graduação em Odontologia da UEPG.

Este conteúdo é restrito a membros do site. Se você é um usuário registrado, por favor faça o login. Novos usuários podem registrar-se abaixo.

Login de Usuários
   
Registro de Novo Usuário
*Campo obrigatório
Abrir conversa
Precisa de ajuda?