Avaliação da força liberada por fios ortodônticos…

Avaliação da força liberada por fios ortodônticos…

Vol. 3 – Número 13 – 2011 Artigo Original 407-413 Avaliação da força liberada por fios ortodônticos de níquel-titânio associados a bráquetes autoligante Avalied of the deactivated force by termoatived nickel-titanium wire associated with self-ligation brackets Temístocles Uriarte Zucch Celestino Nóbrega Jairo J. Benetti Márcio Rivero Gick Sérgio Ricardo Jakob Franco Arsati Resumo O presente estudo teve como objetivo avaliar a força liberada por fios ortodônticos de Níquel-Titânio (Niti) termoativados de secção redonda 0,016¨, quando submetidos a deflexões de 4, 3,5, 3, 2,5, 2, 1,5, 1, 0,5 e 0 mm. Foram selecionadas seis diferentes marcas comerciais de fios (GAC®, Ormco®, Morelli®, Aditek®, US Company® e 3M®, para cada marca comercial foram realizados dez ensaios. Para a realização dos ensaios foi desenvolvido um protótipo, com braquetes autoligantes GAC®, onde o fio ortodôntico foi adaptado. Esse sistema foi colocado em uma máquina de ensaios (EMIC DL 2000), calibrada em 5Kgf e com velocidade de 1mm/min. Todos os ensaios foram realizados em temperatura constante. Por meio de um software os valores de desativação (g) foram registrados e demonstrados através de gráficos de força em função da deflexão, finalizando 60 ensaios. As variáveis foram submetidas á análise de variância e ao teste de Turkey para determinar as diferenças entre as marcas comerciais testadas adotando um nível de significância de 5%. Os resultados demonstraram que na desativação de 4mm para 3mm todos os fios apresentaram redução acentuada de força, característica comum dos fios termoativados e que todas as marcas comerciais estudadas apresentaram liberação de força relativamente constante. Descritores: Movimentação Ortodôntica. Fios Ortodônticos. Biomecânica. Abstract The purpose of this study was to evaluate the deactivation force of Nickel-Titanium termoatived wire with round diameter of 0.016¨, when put into 4; 3.5; 3; 2.5; 2; 1.5, 1, 0.5 and 0 mm deflections. For this purpose was used six different wire trade make   Gac® ,Ormco® ,Morelli® ,Aditek®Us Company®and 3M®)for each trade make was done ten rehearsals. For the test a prototype was developed, with self-ligation brackets GAC®, where orthodontic wire was adapted. The system was adapted in a Universal rehearses machine (EMIC DL 2000) adjusted in 5kgf and with speed of 1mm/min. All the rehearsals were done in constant temperature. Through software the activation values (g) were registered and showed by the power graphics in relation to the deflection, totalizing 60 rehearsals. The variables were subjected to the analysis of variance and test of Turkey to determine the differences between trademarks tested by adopting a significance level of 5%. The result showed that the deactivation of 4mm to 3mm all wires showed severe redution in force, a common characteristic of thermal activated wires and all trademarks studied had relatively constant release of force. Descriptors: Orthodontic Movement. Orthodontic Wire. Biomechanics. Mestre em Ortodontia. Professor Titular da Faculdade CIODONTO. Doutor em Ortodontia. Professor Titular da Faculdade CIODONTO. Mestre em Ortodontia. Professor Titular da Faculdade CIODONTO. Márcio Rivero Gick.Mestre em Ortodontia. Professor Titular da Faculdade CIODONTO. Mestre em Ortodontia. Professor Titular da Faculdade CIODONTO. Doutor do Programa de Pós-Graduação do CPO São Leopoldo Mandic.

Este conteúdo é restrito a membros do site. Se você é um usuário registrado, por favor faça o login. Novos usuários podem registrar-se abaixo.

Login de Usuários
   
Registro de Novo Usuário
*Campo obrigatório
Abrir conversa
Precisa de ajuda?