Estudo comparativo da radiopacidade de cimentos endodônticos avaliado por meio de sistema radiográfico digital

Estudo comparativo da radiopacidade de cimentos endodônticos avaliado por meio de sistema radiográfico digital

Vol. 8 – Número 30 – 2017 CADERNO DE ODONTOLOGIA CLÍNICA Artigo de Endodontia Artigo original/Original article Página 130-135 Estudo comparativo da radiopacidade de cimentos endodônticos avaliado por meio de sistema radiográfico digital Evaluation of the radiopacity of endodontic cements using digital radiograph system: comparative study. Fabio Carmona Tirintan1 Carlos Eduardo Fontana2 Alexandre Sigrist de Martin3 Carlos Eduardo da Silveira Bueno4 Daniel Guimarães Pedro Rocha2 Wânia Christina Figueiredo Dantas5 Resumo A radiopacidade e especificação foram avaliadas de acordo com a norma padrão ISO6876/2001. Para a análise da radiopacidade, 10 placas acrílicas foram confeccionadas com seis furos, cada um com 10,0 mm de diâmetro e 2,0 mm de espessura, e preenchidos com cinco cimentos estudados: AH Plus, Endofill, EndoREZ, Sealapex e MTA Fillapex, e como controle foi utilizada guta-percha. Imagens radiográficas digitais dos espécimes foram importadas do software Digora 1.51. Um densitômetro de alumínio foi utilizado como um instrumento de medição da densidade radiográfica na comparação das amostras, e o valor da radiopacidade foi determinado de acordo com essa densidade radiográfica (mmAl). Os resultados foram analisados estatisticamente por Kruskal-Wallis e complementados por Student-Newman-Keuls. Os cimentos testados apresentaram diferenças estatisticamente significativas entre eles (p<0,05). Os valores da radiopacidade dos cimentos em ordem decrescente em escala de alumínio foram os seguintes: AH Plus (14.86),  Sealapex (13.50), Endofill (12.87), MTA Fillapex (11.90) e EndoREZ (10.27). Concluiu-se que a maior radiopacidade ocorreu no cimento AH Plus, porém, todos os materiais testados preencheram os requisitos das normas ISO 6876/2001. Descritores: Cimento endodôntico, radiopacidade, digital de radiografia. Abstract Specification and radiopacity were evaluated according to standard ISO 6876/2001. For the analysis of radiopacity, 10 acrylic plates were made with six holes, each with 10.0 mm diameter and 2.0 mm thick, and filled with the five studied cements: AH Plus, Endofill, EndoREZ, Sealapex, MTAFillapex, and a control guta-percha was used. Digital radiographic images of the specimens were imported from Digora software version 1.51. An aluminum densitometer was used as an instrument for measure the radiographic density in the comparison sample, and the value of optical density was determined in accordance with this radiographic density (mm Al). The results were statistically analyzed using Kruskal-Wallis test and complemented by Student-Newman-Keuls test. The tested cements showed significant statistically differen-ces between them (p < 0.05). The values of the radiopacity of the cement in decreasing scale aluminum were the following: AH Plus (14.86), Sealapex (13.50), Endofill (12.87), MTA Fillapex (11.90), and EndoREZ (10.27). It was concluded that most radiopacity occurred in AH Plus cement, however, all materials tested met the requirements of ISO 6876/2001 standards. Descriptors: Endodontic cement, radiopacity, digital radiography. 1 Me. em Endodontia – Centro de Pesquisas Odontológicas – SLMANDIC, Prof. de Endodontia e Coord. do curso de Odontologia – UNIC. 2 Dr. em Endodontia – SLMANDIC, Prof. de Endodontia – PUC Campinas, Prof. de Endodontia  – SLMANDIC. 3 Dr. em Endodontia – UNICAMP, Prof. de Endodontia  – SLMANDIC. 4 Dr. em Endodontia – UNICAMP, Prof. de Endodontia – PUC Campinas, Prof. de Endodontia  – SLMANDIC. 5 Mª. e Doutoranda em Endodontia – Centro de Pesquisas Odontológicas – SLMANDIC.

Este conteúdo é restrito a membros do site. Se você é um usuário registrado, por favor faça o login. Novos usuários podem registrar-se abaixo.

Login de Usuários
   
Registro de Novo Usuário
*Campo obrigatório
Abrir conversa
Precisa de ajuda?