Avaliação in vivo do localizador apical Novapex na determinação do comprimento do dente

Avaliação in vivo do localizador apical Novapex na determinação do comprimento do dente

Vol. 4 – Número 16 – 2013   CADERNO DE ENDODONTIA    Artigo original / Original article   Página 628-631 Avaliação in vivo do localizador apical Novapex na determinação do comprimento do dente In vivo evaluation of Novapex apex locator in determining the length of the tooth   Maria Isabel Anastacio Faria1 Júlia Búrigo Lima Moritz2 Sérgio Herrero de Moraes3 .     Resumo O objetivo deste estudo é avaliar, in vivo, a confiabilidade do localizador apical Novapex na determinação do comprimento do dente, submetido ao tratamento endodôntico. Foram avaliados um total de 29 canais de 15 pacientes com indicação endodôntica. Os dentes foram anestesiados e isolados com dique de borracha, seguidos da abertura coronária, acesso radicular e exploração do canal com lima # 15. A Odontometria foi realizada utilizando-se o localizador apical com uma lima ajustada ao diâmetro do canal, que foi introduzida até o aparelho acusar a escala 0 do visor (forame). O dente foi radiografado com a lima nessa medida e as radiografias foram digitalizadas e analisadas no programa  Image Toll  versão 3.00 para que os comprimentos em mm da distância entre o ápice radiográfico e a ponta da lima fossem mensurados. Os resultados demonstraram que o localizador apical registrou a posição do instrumento entre 0 a 1mm em 24 canais (82,75%), sendo que em 6 canais (20,68%) as medidas ficaram exatamente no zero. Em 4 canais (13,79%) observou-se, radiograficamente, o transpasse do instrumento pelo forame radiográfico, porém em 3 canais o valor foi menor que 0,5mm. Medidas compreendidas entre 0 e 1mm foram consideradas ideais. O localizador apical Novapex mostrou ser seguro, prático e confiável, porém, ainda carente de uma radiografia de confirmação.   Descritores: Endodontia, Odontometria, forame apical.   Abstract The objective of this study was to evaluate in vivo the reliability of Novapex apex locator in determining the length of tooth submitted to endodontic treatment. A total of 29 channels of 15 patients referred to endodontics, were evaluated. Teeth were anesthetized and isolated with rubber dam, followed by coronal opening, root access and exploration of the canal with file # 15. The Odontometry was performed using the apex locator with a file adjusted to the diameter of the canal. The instrument was introduced until show scale 0 of the display (foramen). The tooth was radiographed with the file inn this position and radiographs were digitized and analyzed in the Image Toll version 3.00 program to measure the length in mm of the distance between the radiographic apex and the tip of the file. Results showed that the apex locator registered the position of the instrument between 0 and 1mm in 24 canals (82.75%), and for 6 canals (20.68%) the measures were exactly at zero. Through radiographs was observed on 4 canals (13.79%) the overlapping of the instrument by radiographic foramen, but for 3 of them the value was lower than 0.5mm. Measures between 0 and 1mm were considered ideal. The Novapex apex locator has is safe, practical and reliable. However it still requires confirmation by radiographic exam.   Descriptors: Endodontics; Odontometry; appical foramen.   1 Profa. Dra. do Curso de Odontologia da Faculdade Herrero.  2 Esp. em Endodontia – Faculdade Herrero.  3 Prof. Dr. do Curso de Odontologia UFPR .  

Este contenido está restringido a los miembros del sitio. Si eres un usuario existente, por favor, accede. Los nuevos usuarios pueden registrarse a continuación.

Acceso de usuarios existentes
   
Registro de un nuevo usuario
*Campo necesario
Abrir conversa
Precisa de ajuda?